Industrial Products

NTD display

Network Time Display 2 & 4 Inches

ALS-NTDIS-01-D (4 Inches) ALS-NTDIS-01 (4 Inches) ALS-NTDIS-02-D (2 Inches) ALS-NTDIS-02 (2 Inches)
  • NTP time display based on microcontroller
  • Interfaces through Ethernet to a Time server using SNTP/NTP protocol
  • Time accuracy better than a second
  • Built in RTC maintains the time in the absence of NTP signal
  • Bright Seven segment numeric modules
  • No_of_days: Hours: Minutes: Seconds & Hours: Minutes: Seconds
  • Presence of Signal loss indicator
  • Display size 4” & 2”
  • Operates off 90V-270V AC
  • Configuration through in built USB to Serial interface

TIME CODE READER

TIME CODE READER

Count Down / Count Up / Universal Time Code readers

Input:

  • Code: Modified IRIG-B modulated code / modified IRIG-B, D.C. level shift code.

Output:

  • Modulated Code: Buffered modulated code in BNC female connector on rear panel.
  • DC shift code: Buffered DCLS output in BNC female connector on rear panel.
  • Rate pulses: 1 pulses /second. (1PPS).

DISPLAY: A 9 digit ultra high bright high 7 segment (RED) display on front panel (in center) representing Days (3digits), Hours (2 digits), Minutes (2 digits), Seconds (2 digits), preceded by sign display (i.e.,) left most display to represent (-) for count down and (+) for count up with a clear gap between seconds, minutes, hours, days and sign digits. Displays come in1”, 2” and 3” heights

OPERATING SUPPLY: 230v AC +/- 10%, 50 Hz.

Dentist Chair Controller

Dentist Chair Controller

Dentist Chair Controller

The operation of a Dentist’s chair is controlled with the aid of two control boards one located at the base , close to the Power Supply and Drive motors and the second in the trolley . The base board controls the UP/DOWN and FRONT/BACK movements of the Chair and also provides for storing two programmed positions , and gargling function. The Trolley Controller allows control of the Drill motor – speed increase/decrease , Forward/Reverse direction of Rotation Hand/Foot mode of operation , control of X-Ray , Tumbler , Spittoon , Lamps and Scalar . A compact membrane type Keyboard is also provided.

GSM IOT Status Monitoring Unit

GSM IOT Status Monitoring Unit

GSM IOT Status Monitoring Unit

Transfers error status in machinery, to the cloud, in real time, facilitating data collection and improved maintenance.

IOT Gateway

IOT Gateway

IOT Gateway

Collects Data from IOT Power Monitors and transfers the Data to the Cloud via GSM . Compact and operates off a Power Adaptor.

IOT Power Monitor

IOT Power Monitor

IOT Power Monitor

Monitors the Energy consumed by appliances and transmits the information over an RF link to the IOT Gateway which in turn transmits it to the cloud.

Power Control Unit

Power Control Unit

Power Control Unit

Multiple Microcontrollers are used to exercise operational sequences to test the reliable operation of external power switches and to monitor the levels of external system batteries, voltages etc. Multiple Microcontrollers programmed through an isolated RS485 interface. Industrial Grade requiring a number of test procedures / reports.

Modular Test Interface Package

Modular Test Interface Package

Modular Test Interface Package

Sub Rack housing up to six multiplexer cards interconnected through a backplane and communicating amongst themselves through a RS485 serial link. Gathers information like pulse occurrence and duration, simultaneously in up to 900 channels and transfers the data in real time to a host computer through an Ethernet link. The inter card communication uses a master/slave principle.

Multiplexer card for Modular Test Interface Package

Multiplexer card for Modular Test Interface Package

Multiplexer card for Modular Test Interface Package

The card is capable of gathering pulse data simultaneously in up to 160 channels and includes a microcontroller and a high-density FPGA.

Stimulii Generator

Stimulii Generator

Stimulii Generator

Industrial Grade unit that houses multiple programmable current and voltage stimuli required for System Checks . Multiple Microcontrollers programmed through an isolated RS485 interface.

System Test Package – Thermovac Grade

System Test Package – Thermovac Grade

System Test Package – Thermovac Grade

Test package to analyse digital signals in real time, under prescribed environmental conditions and transfer data to an external computer in real time. High density FPGA’s are used.

Control Synchronisation unit

Control Synchronisation unit

Control Synchronisation unit

Accurately Synchronises timing signals in the Remote mode and generates timing pulses in the local mode. Requires a number of type and routine tests to be done during approval and routine production.

Cell Voltage Acquisition System

Cell Voltage Acquisition System

Cell Voltage Acquisition System

Isolated monitoring of Electrolyser Cell Voltages in a Caustic Soda plant to enable optimization of plant output and effective maintenance. All voltages are isolated, and data is transferred through MODBUS RTU protocol to a Host computer. Modular in construction.

Starter Motor Endurance Rig Controller

Starter Motor Endurance Rig Controller

Starter Motor Endurance Rig Controller

Parametric Endurance Testing of Starter Motors – Data including Voltage, Current etc, are monitored and transferred, over specified number of cycles, to establish the performance of Starter Motors.

Programmable Cell Voltage Simulator

Programmable Cell Voltage Simulator

Programmable Cell Voltage Simulator

Self contained unit facilitating generation of Simulated Battery voltages for Test purposes. Programmable from a remote Host through an isolated RS485 Serial link.

Telemetry Telecommand Simulator

Telemetry Telecommand Simulator

Telemetry Telecommand Simulator

FPGA based unit to simulate digital command sequences and telemetry data at different clock speeds.

Hydrogen in Sodium Monitor Display unit

Hydrogen in Sodium Monitor Display unit

Hydrogen in Sodium Monitor Display unit

Industrial Grade unit to monitor/display the concentration of Hydrogen in Sodium. Works in conjunction with an Industrial Grade Preamplifier and provides a number of alarm features. Requires a number of type and routine tests to be done during approval and routine production.

GPS based clock

GPS based clock

Receives real time from Satellites through GPS device and displays accurate time in hours, minutes and seconds.

Hours, Minutes and Seconds: Seven segment display using SMD LEDs with blinking second’s indications. Digit size 90mmX45mm. Displays local time in 24 hours format.

Time information from satellites is received through internal GPS receiver in master mode. In slave mode, units are updated by the Master through an RS485 differential serial twisted pair of wires. Antenna for the GPS can be extended up to 5 meters.

Built in RTC enables time display in the absence of GPS data.

Compact, elegant wall mountable metal enclosure with built in power supply; operates off 230V AC, 50Hz.

Typical configuration requires a single master which can be connected to multiple slaves through a daisy chain connection.

Xilinx PCI card

Xilinx PCI card

Xilinx PCI card

High density FPGA in a PCI data acquisition card. Provides interface for 16 Analog inputs, 8 DAC outputs, 1 Mb Static Ram, 128 digital inputs and 128 digital outputs.

Production Display

Production Display

Production Display

Large display displays 3 lines of information relating to production data. A Sensor collects production data in real time, converts it to suitable parameter and transfers this to a host computer through an isolated Serial RS 485 link.

Counter 4x4

Counter 4x4

Counter 4x4

Four channel 4 digit industrial counter.

8 channel Alarm Annunciator

8 channel Alarm Annunciator

8 channel Alarm Annunciator

  • Number of alarm points: 8
  • Window size: 32.5mm ´ 32.5mm
  • Display device: Super bright low power consuming red LED’s
  • Facia type: Individual windows front replaceable
  • Flash rate: 60 Flash/min
  • Cabinet mounting: Din Standard
  • Field Contact Operation: Potential free contacts, NO/NC selectable by Dip switch present at the back panel.
  • Built in push buttons: Silence, Acknowledge, Reset, Test
  • Provision for remote push buttons (Optically Isolated Inputs)
  • Built in audio alarm (Buzzer)
  • Potential free contact for hooter and system healthy
  • System healthy indication on front panel
  • Operation sequences: ISA standard sequences. Sequence selection using DIP switch present at the back panel
  • Interrogation voltage: 24V DC
  • Ambient temperature: 0 - 50°C
  • Dimensions (in mm): 144 ´144´100(W´H´D)
  • Mounting: Flush panel mounting with cover mounted screw clamps
  • Supply voltage: 100V to 260V AC, 50Hz

RPM display

ALS-RPMDIS-01

RPM display

  • Display 4 digit Seven Segment - 20mm height
  • Range 0 – 9999 rpm
  • Resolution 1 rpm
  • Sensor Proximity – PNP , NPN ; Sine wave 250mV rms min
  • Sensor power supply DC 12V, 0.30A max provided
  • Operating temperature 0 to 50 deg C
  • Operating Principle Selectable -Pulse counting or Period inverse
  • Power supply 100V to 260V AC , 50 HZ
  • Enclosure Standard DIN – 48mm x 96mm

Water level controller

ALS-WLCTRL-01

Water level controller

  • Automatic water level controller is a compact, elegant wall mounted low cost unit to automatically maintain the level of water in overhead tanks in households, offices and industries.
  • Up to 8 sensors located in the underground sump and overhead tank to provide control and indication of water level
  • LED’s on front panel indicate Controller operation, Sump dry and Tank full status
  • Switch allows manual operation of the motor
  • Controls up to 1/2HP, Single Phase, 230V AC, 50Hz motor
  • Sensor cabling requirement depends on the installation.
  • Operates off 230V, 50Hz Single Phase power supply.

Relay boards

Relay boards

  • Relay with input led indication
  • Makes available: omron, oen, goodsky, pla
  • Channels: 1 change over, 2 change over
  • Coil voltage: 12volt/24volt dc
  • Contacts: industrial grade terminals-phoenix, xynia, degson
  • Contact type: mkds/mkdsn/double decker
  • Current rating: above 10amps
  • Available channels: 1, 2, 4, 8, 16, 24, 32 (as per requirement)
  • Mounting type: din rail (72mm/108mm)

Note: customized boards can be developed as per the specification.

Signal termination boards

Signal Termination boards

  • Available Types: D-Type straight connectors Male & Female, FRC straight connector’s male to terminals
  • Available contacts:
     
    D-Type-9, 15, 25, 37, 50
    FRC-10, 16, 20, 26, 34, 40, 50, 64
  • Mounting type: DIN rail (72mm/108mm)
  • CONTACT TYPE: MKDS/MKDSN/DOUBLE DECKER
  • CONTACTS: INDUSTRIAL GRADE TERMINALS-PHOENIX, XYNIA, DEGSON

Note: Customised boards can be developed as per the specification.